Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Automating an access control system can significantly enhance the convenience and security of a home or office. Shelly Plus UNI, a versatile and compact Wi-Fi module, is an excellent choice for this task. Designed for low-voltage applications, Shelly Plus UNI can control various sensors and devices, making it ideal for integrating with an access control buzzer.

image-20240628-131516.png

Required Components

Wiring

Power Supply: Connect power to the Shelly Plus UNI. Ensure the voltage is within the supported range (12V-36V DC or 12V-24V AC).

If powering Shelly Uni via AC, connections should be made to VAC1 and VAC2

Most Access Control Systems are powered via 24vAC and can be used to power Shelly Plus UNI.

If suitable power is not available directly from the Access Control System then an external power supply must be used.

image-20240628-133354.png

Buzzer Connection:

  • Connect one terminal of the buzzer to the OUT1 terminal on the Shelly Plus UNI.

  • Connect the other terminal of the buzzer to the power supply's ground or negative terminal.

Example System Diagram

image-20240628-142440.png

image-20240628-142336.png

Shelly Plus UNI Wiring Diagram

image-20240628-145937.png

Legend

VAC1

Red

8-24 VAC / 9-28 VDC power supply input 1

VAC2

Black

8-24 VAC / 9-28 VDC power supply input 2

ANALOG IN

White

Analog input

SENSOR VCC

Yellow

Power supply for 1-Wire sensors

DATA

Blue

1-Wire data line

+ 5 VDC

Gray

5 VDC power supply positive input

GND

Green

5 VDC power supply ground input and Sensor ground

COUNT IN

Purple

Counter input

IN1

Orange

Digital input 1

IN2

Brown

Digital input 2

OUT 1

Black

Solid-state relay 1 terminals

OUT 2

Black

Solid-state relay 2 terminals

Shelly Smart Control App Configuration

  1. Open the Shelly Smart Control app.

  2. Tap the blue + icon at the bottom right.

  3. Tap + Add a New Device.

Picture1.png

  1. Tap Add Via WiFi (AP Scan).

Picture2.png

  1. Tap Next.

  2. Tap the relay.

  3. Tap Next.

  4. Tap + Add Device. The inclusion process lasts for several moments.

Picture3.png

  1. Type a name for the device.

  2. Select an image to represent the device in the Smart Control app.

  3. Select the Room to add the device to. Tap Save.

  4. Tap Next. The device is associated with your Smart Control account.

Picture4.png

The device is now included in Shelly Smart Control app and registered to a Cloud Account. It can be controlled from any location where internet is available.

Updating the Firmware of the Device

  1. Tap the device to update.

  2. Tap the Settings button.

  3. Tap the Firmware version dropdown.

  4. The option to enable auto-update is presented, as is the current and available firmware version. Tap Update, then tap Update again.

  5. The device updates

Picture5.png

The update process may take several moments and require resetting the device. It is not recommended to perform a firmware update if the device is not physically reachable.

Output 1

In Shelly Smart Control, Output 1 is designated for buzzer control. This functionality can be utilized independently within the application by simply pressing the button. Alternatively, you have the option to expand its capabilities by incorporating timers, schedules, and creating a "Scene" to trigger a Push Notification upon button activation. Conducting experiments in this area will result in the development of a versatile system suitable for various scenarios.

image-20240628-143354.pngIMG_7CACAD48A2DF-1.png

Shelly Plus Uni Settings

Shelly Plus UNI provides an extensive array of settings and customizable variables that go beyond the content of this document. To access more information, kindly consult the linked article on the right.

  • No labels