Basic Load Shedding Using a Script

Basic Load Shedding Using a Script

Load shedding is the intentional, temporary reduction of electrical power supply to certain appliances and/or circuits. This is done to reduce electrical consumption and is a cost saving measure. Load shedding helps to balance supply and demand, ensuring the stability of the overall electrical system during times of high demand or when there are issues with power generation.

AdobeStock_608968611.jpeg

 

 

 

 

image-20240904-153134.png

 

Why use a Script for Load Shedding?

Using a script running on a Shelly Pro 3EM has a lot of advantages, especially when combined with various other Shelly relays. Scripting can offer a highly customizable and extremely efficient way to accomplish load shedding. A script either from the repopulated Shelly library or manually entered is used to create a system where you can dynamically control and shed loads based on certain conditions, such as high energy consumption or demand.

Prerequisites

These devices will be used to gather the consumption data required for load shedding

 

PM devices can be used to gather additional consumption data and control circuits during shedding.

These devices will be used to control various loads during shedding.

Steps to Setting up Load Shedding

1. Setting Up Shelly Pro 3EM

Wire and Configure the Pro 3EM

  1. Install and Configure: Install the Pro 3EM per the diagram below to monitor the energy consumption of the entire home.

In scenarios where CT-B is not used, it is advised to repurpose it to cover Neutral. This requires recalibrating in the device’s settings.

 

 

 

Legend

Terminals

Cables

A

Phase A input

LA

Phase A live (110-240 V) cable

B

Phase B input

LB

Phase B live (110-240 V) cable

C

Phase C and power supply input

LC

Phase C live (110-240 V) cable

N

Neutral terminal

L

Mono-phase live (110-240 V) cable

IA

Phase A current transformer input

N

Neutral cable

IB

Phase B current transformer input

Current transformers

IC

Phase C current transformer input

CTA

Phase A current transformer

IN

Neutral current transformer input

CTB

Phase B current transformer

 

 

CTC

Phase C current transformer

 

 

CTN

Neutral current transformer

  1. Connect to Network: Using Shelly Smart Control, connect the Pro 3EM to your network.

 

  1. Shelly Cloud (optional): Add Shelly Pro 3EM to a Shelly Cloud account for remote access.

2. Set Up Additional Shelly Relays

 

 

  1. Install Shelly Relays: Install Shelly relays to control the specific loads you want to manage.

  1. Connect to Network: Using Shelly Smart Control, connect the Pro 3EM to your network.

 

  1. Shelly Cloud (optional): Add Shelly Pro 3EM to a Shelly Cloud account for remote access.

3. Adding the Load Shedding Script to the Host Pro 3EM

 

 

 

 

  1. Navigate to the Scripts Menu: Shelly Smart Control has a section for Scripts for each compatible device. For Load Shedding we will use a Shelly Pro 3EM. With that device select click on the { } Icon.

 

 

 

 

 

 

 

 

  1. Click Open Library and Select the Script: On this screen we will select; Load Shedding with Shelly Pro 4PM and Pro 3EM. Expand this option and press the button labeled Insert Code

 

 

 

 

 

 

 

  1. Name the Script: At the top of the screen give your script a name.

  1. Setting the Devices to be Shed: The devices to be shed are specified under first_to_last_to_shed

 

 

 

 

 

 

 

 

 

 

 

 

  1. Configuring the Shedding Trigger Parameter:

    1. max_before_shedding

  1. Configuring the Reading of Devices:

    1. min_before_re_adding

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  1. Configuring the Polling Frequency:

    1. poll_time

      1. Minimum interval between executing normal on/off steps

    2. short_poll

      1. Interval after toggling on a device assumed to be already on

 

 

 

 

 

 

 

 

 

  1. Set Logging Parameters:

    1. logging

      1. will populate the Activity Log

 

  1. Set Simulation Parameters:

    1. simulation_power

      1. Set this to manually test in the console

 

 

 

 

 

  1. Saving and Executing the Script:

    1. Click the Save Button in the top right next the the Script Name and Play Button

    2. Click the Play Button in the top right next to the Script Name.

5. System Testing

 

 

 

  1. Simulate High Load: Increase the load to trigger the thresholds.

  2. Verify Script Actions: Check if the Activity Log to verify the Load Shedding Script is executing the defined commands.

 

 

 

 

 

 

By following these steps, you can effectively use a Script with Shelly Pro 3EM and various Shelly relays to implement load shedding, helping to manage and reduce energy consumption dynamically.

Related content

Adding On Production Monitoring for the Complete Load Shedding Experience
Adding On Production Monitoring for the Complete Load Shedding Experience
More like this
Advanced Load Shedding Using a Script
Advanced Load Shedding Using a Script
More like this
Load Shedding with Webhooks
Load Shedding with Webhooks
More like this
Load Shedding with Shelly Pro 3EM and Shelly EM/PM Products
Load Shedding with Shelly Pro 3EM and Shelly EM/PM Products
More like this